Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Marine, OIL,GAS & Petrochemical Cables 

British Standard Shipwiring cables to BS 6883

Flexible armoured screened Instrument cables

Flexible armoured screened Instrument cables

Manufactured in both pairs and triples these 150/250V instrumentation cables provide collective or individual screening through the use of metallic foils and drain wires. Offering good flexibility for installation in confined spaces or where difficult routing is necessary, the galvanised steel wire braid provides mechanical protection

Core Identification

Pairs :  Each pair black, white and numbered
Triples :   Each triple black, white, red and numbered
Alternative colour codes are available

Technical Information

Voltage rating 150/250V
Conductors Tinned, BS6360 class 2 or class 5
Temperature rating +90°C maximum conductor temperature
Static temperature rating -30°C to +90°C
Bending radius (static) 8 x cable O/D
Flame retardant IEC60332 part 3A, BS4066 part 3A

Technical Data

No. of
Pairs
Nominal Conductor
Cross-Sectional
Area mm²
Diameter over
inner sheath
min-max mm
Diameter over
outer sheath
min-max mm
 Pairs collective
 3  0.75  12.6 - 14.5  16.7 - 19.0
 7  0.75  16.6 - 18.7  20.9 - 23.8
 12  0.75  21.7 - 24.2  26.4 - 29.5
 20  0.75  27.3 - 30.1  33.3 - 37.1
 27  0.75  31.1 - 34.2  37.4 - 41.4
 37  0.75  34.4 - 37.7  41.0 - 45.0
 3  1  13.3 - 15.3  17.4 - 19.8
 7  1  17.6 - 19.8  22.1 - 25.1
 12  1  23.1 - 25.7  28.0 - 31.2
 20  1  29.1 - 31.9  35.3 - 39.2
 27  1  33.3 - 36.6  39.7 - 44.2
 37  1  36.9 - 40.3  43.7 - 48.3
 Pairs individual
 1  0.75  7.3 - 9.0  11.1 - 12.9
 3  0.75  12.6 - 14.5  16.7 - 19.0
 7  0.75  16.9 - 19.0  21.4 -24.3
 12  0.75  21.3 - 23.7  26.1 - 29.2
 20  0.75  27.0 - 29.8  33.2 - 37.0
 27  0.75  30.8 - 33.9  37.3 - 41.3
 37  0.75  25.9 - 39.3  42.9 - 47.5
 1  1  7.7 - 9.5  11.5 - 13.4
 3  1  13.5 - 15.5  17.6 - 20.0
 7  1  18.0 - 20.1  22.5 - 25.4
 12  1  22.8 - 25.4  28.6 - 31.8
 20  1  28.8 - 31.6  35.2 - 39.0
 27  1  32.8 - 36.0  39.5 - 44.0
 37  1  38.5 - 42.3  45.7 - 50.4
No. of
Triples
Nominal Conductor
Cross-Sectional
Area mm²
Diameter over
inner sheath
min-max mm
Diameter over
outer sheath
min-max mm
 Triples collective
 3   0.75   14.2 - 16.2   18.3 - 20.7 
 7   0.75   19.4 - 21.9   24.0 - 27.0 
 12   0.75   24.2 - 26.8   29.3 - 32.9 
 3   1   15.1 - 17.1   19.4 - 22.2 
 7   1   20.9 - 23.4   25.6 - 28.7 
 12   1   25.8 - 28.5   31.8 - 35.5 
 Triples individual
 1   0.75   7.7 - 9.4   11.5 - 13.3 
 3   0.75   14.2 - 16.2   18.6 - 20.9 
 7   0.75   19.7 - 22.1   24.4 - 27.4 
 12   0.75   24.4 - 27.1   30.4 - 34.1 
 1   1   8.4 - 10.1   12.1 - 14.0 
 3   1   15.0 - 17.2   19.4 - 22.3 
 7   1   21.0 - 23.5   25.7 - 28.8 
 12   1   26.2 - 28.9   32.2 - 36.0